Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
JAMA ; 329(14): 1170-1182, 2023 04 11.
Artículo en Inglés | MEDLINE | ID: mdl-37039791

RESUMEN

Importance: Preclinical models suggest dysregulation of the renin-angiotensin system (RAS) caused by SARS-CoV-2 infection may increase the relative activity of angiotensin II compared with angiotensin (1-7) and may be an important contributor to COVID-19 pathophysiology. Objective: To evaluate the efficacy and safety of RAS modulation using 2 investigational RAS agents, TXA-127 (synthetic angiotensin [1-7]) and TRV-027 (an angiotensin II type 1 receptor-biased ligand), that are hypothesized to potentiate the action of angiotensin (1-7) and mitigate the action of the angiotensin II. Design, Setting, and Participants: Two randomized clinical trials including adults hospitalized with acute COVID-19 and new-onset hypoxemia were conducted at 35 sites in the US between July 22, 2021, and April 20, 2022; last follow-up visit: July 26, 2022. Interventions: A 0.5-mg/kg intravenous infusion of TXA-127 once daily for 5 days or placebo. A 12-mg/h continuous intravenous infusion of TRV-027 for 5 days or placebo. Main Outcomes and Measures: The primary outcome was oxygen-free days, an ordinal outcome that classifies a patient's status at day 28 based on mortality and duration of supplemental oxygen use; an adjusted odds ratio (OR) greater than 1.0 indicated superiority of the RAS agent vs placebo. A key secondary outcome was 28-day all-cause mortality. Safety outcomes included allergic reaction, new kidney replacement therapy, and hypotension. Results: Both trials met prespecified early stopping criteria for a low probability of efficacy. Of 343 patients in the TXA-127 trial (226 [65.9%] aged 31-64 years, 200 [58.3%] men, 225 [65.6%] White, and 274 [79.9%] not Hispanic), 170 received TXA-127 and 173 received placebo. Of 290 patients in the TRV-027 trial (199 [68.6%] aged 31-64 years, 168 [57.9%] men, 195 [67.2%] White, and 225 [77.6%] not Hispanic), 145 received TRV-027 and 145 received placebo. Compared with placebo, both TXA-127 (unadjusted mean difference, -2.3 [95% CrI, -4.8 to 0.2]; adjusted OR, 0.88 [95% CrI, 0.59 to 1.30]) and TRV-027 (unadjusted mean difference, -2.4 [95% CrI, -5.1 to 0.3]; adjusted OR, 0.74 [95% CrI, 0.48 to 1.13]) resulted in no difference in oxygen-free days. In the TXA-127 trial, 28-day all-cause mortality occurred in 22 of 163 patients (13.5%) in the TXA-127 group vs 22 of 166 patients (13.3%) in the placebo group (adjusted OR, 0.83 [95% CrI, 0.41 to 1.66]). In the TRV-027 trial, 28-day all-cause mortality occurred in 29 of 141 patients (20.6%) in the TRV-027 group vs 18 of 140 patients (12.9%) in the placebo group (adjusted OR, 1.52 [95% CrI, 0.75 to 3.08]). The frequency of the safety outcomes was similar with either TXA-127 or TRV-027 vs placebo. Conclusions and Relevance: In adults with severe COVID-19, RAS modulation (TXA-127 or TRV-027) did not improve oxygen-free days vs placebo. These results do not support the hypotheses that pharmacological interventions that selectively block the angiotensin II type 1 receptor or increase angiotensin (1-7) improve outcomes for patients with severe COVID-19. Trial Registration: ClinicalTrials.gov Identifier: NCT04924660.


Asunto(s)
COVID-19 , Receptor de Angiotensina Tipo 1 , Sistema Renina-Angiotensina , Vasodilatadores , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Angiotensina II/metabolismo , Angiotensinas/administración & dosificación , Angiotensinas/uso terapéutico , COVID-19/complicaciones , COVID-19/mortalidad , COVID-19/fisiopatología , COVID-19/terapia , Hipoxia/tratamiento farmacológico , Hipoxia/etiología , Hipoxia/mortalidad , Infusiones Intravenosas , Ligandos , Oligopéptidos/administración & dosificación , Oligopéptidos/uso terapéutico , Ensayos Clínicos Controlados Aleatorios como Asunto , Receptor de Angiotensina Tipo 1/administración & dosificación , Receptor de Angiotensina Tipo 1/uso terapéutico , Sistema Renina-Angiotensina/efectos de los fármacos , SARS-CoV-2 , Vasodilatadores/administración & dosificación , Vasodilatadores/uso terapéutico
2.
J Clin Transl Sci ; 7(1): e29, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36845316

RESUMEN

Background: Many clinical trials leverage real-world data. Typically, these data are manually abstracted from electronic health records (EHRs) and entered into electronic case report forms (CRFs), a time and labor-intensive process that is also error-prone and may miss information. Automated transfer of data from EHRs to eCRFs has the potential to reduce data abstraction and entry burden as well as improve data quality and safety. Methods: We conducted a test of automated EHR-to-CRF data transfer for 40 participants in a clinical trial of hospitalized COVID-19 patients. We determined which coordinator-entered data could be automated from the EHR (coverage), and the frequency with which the values from the automated EHR feed and values entered by study personnel for the actual study matched exactly (concordance). Results: The automated EHR feed populated 10,081/11,952 (84%) coordinator-completed values. For fields where both the automation and study personnel provided data, the values matched exactly 89% of the time. Highest concordance was for daily lab results (94%), which also required the most personnel resources (30 minutes per participant). In a detailed analysis of 196 instances where personnel and automation entered values differed, both a study coordinator and a data analyst agreed that 152 (78%) instances were a result of data entry error. Conclusions: An automated EHR feed has the potential to significantly decrease study personnel effort while improving the accuracy of CRF data.

3.
Chest ; 162(5): 982-994, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35780813

RESUMEN

BACKGROUND: Convalescent plasma has been one of the most common treatments for COVID-19, but most clinical trial data to date have not supported its efficacy. RESEARCH QUESTION: Is rigorously selected COVID-19 convalescent plasma with neutralizing anti-SARS-CoV-2 antibodies an efficacious treatment for adults hospitalized with COVID-19? STUDY DESIGN AND METHODS: This was a multicenter, blinded, placebo-controlled randomized clinical trial among adults hospitalized with SARS-CoV-2 infection and acute respiratory symptoms for < 14 days. Enrolled patients were randomly assigned to receive one unit of COVID-19 convalescent plasma (n = 487) or placebo (n = 473). The primary outcome was clinical status (disease severity) 14 days following study infusion measured with a seven-category ordinal scale ranging from discharged from the hospital with resumption of normal activities (lowest score) to death (highest score). The primary outcome was analyzed with a multivariable ordinal regression model, with an adjusted odds ratio (aOR) < 1.0 indicating more favorable outcomes with convalescent plasma than with placebo. In secondary analyses, trial participants were stratified according to the presence of endogenous anti-SARS-CoV-2 antibodies ("serostatus") at randomization. The trial included 13 secondary efficacy outcomes, including 28-day mortality. RESULTS: Among 974 randomized patients, 960 were included in the primary analysis. Clinical status on the ordinal outcome scale at 14 days did not differ between the convalescent plasma and placebo groups in the overall population (aOR, 1.04; one-seventh support interval [1/7 SI], 0.82-1.33), in patients without endogenous antibodies (aOR, 1.15; 1/7 SI, 0.74-1.80), or in patients with endogenous antibodies (aOR, 0.96; 1/7 SI, 0.72-1.30). None of the 13 secondary efficacy outcomes were different between groups. At 28 days, 89 of 482 (18.5%) patients in the convalescent plasma group and 80 of 465 (17.2%) patients in the placebo group had died (aOR, 1.04; 1/7 SI, 0.69-1.58). INTERPRETATION: Among adults hospitalized with COVID-19, including those seronegative for anti-SARS-CoV-2 antibodies, treatment with convalescent plasma did not improve clinical outcomes. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov; No.: NCT04362176; URL: www. CLINICALTRIALS: gov.


Asunto(s)
COVID-19 , Adulto , Humanos , COVID-19/terapia , SARS-CoV-2 , Anticuerpos Antivirales , Hospitalización , Resultado del Tratamiento , Sueroterapia para COVID-19
4.
Trials ; 22(1): 221, 2021 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-33743799

RESUMEN

BACKGROUND: Convalescent plasma is being used widely as a treatment for coronavirus disease 2019 (COVID-19). However, the clinical efficacy of COVID-19 convalescent plasma is unclear. METHODS: The Passive Immunity Trial for Our Nation (PassITON) is a multicenter, placebo-controlled, blinded, randomized clinical trial being conducted in the USA to provide high-quality evidence on the efficacy of COVID-19 convalescent plasma as a treatment for adults hospitalized with symptomatic disease. Adults hospitalized with COVID-19 with respiratory symptoms for less than 14 days are eligible. Enrolled patients are randomized in a 1:1 ratio to 1 unit (200-399 mL) of COVID-19 convalescent plasma that has demonstrated neutralizing function using a SARS-CoV-2 chimeric virus neutralization assay. Study treatments are administered in a blinded fashion and patients are followed for 28 days. The primary outcome is clinical status 14 days after study treatment as measured on a 7-category ordinal scale assessing mortality, respiratory support, and return to normal activities of daily living. Key secondary outcomes include mortality and oxygen-free days. The trial is projected to enroll 1000 patients and is designed to detect an odds ratio ≤ 0.73 for the primary outcome. DISCUSSION: This trial will provide the most robust data available to date on the efficacy of COVID-19 convalescent plasma for the treatment of adults hospitalized with acute moderate to severe COVID-19. These data will be useful to guide the treatment of COVID-19 patients in the current pandemic and for informing decisions about whether developing a standardized infrastructure for collecting and disseminating convalescent plasma to prepare for future viral pandemics is indicated. TRIAL REGISTRATION: ClinicalTrials.gov NCT04362176 . Registered on 24 April 2020.


Asunto(s)
COVID-19/terapia , Hospitalización , SARS-CoV-2/patogenicidad , COVID-19/diagnóstico , COVID-19/inmunología , COVID-19/virología , Interacciones Huésped-Patógeno , Humanos , Inmunización Pasiva , Estudios Multicéntricos como Asunto , Ensayos Clínicos Controlados Aleatorios como Asunto , SARS-CoV-2/inmunología , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos , Sueroterapia para COVID-19
5.
Res Sq ; 2021 Mar 02.
Artículo en Inglés | MEDLINE | ID: mdl-33688640

RESUMEN

Background: Convalescent plasma is being used widely as a treatment for coronavirus disease 2019 (COVID-19). However, the clinical efficacy of COVID-19 convalescent plasma is unclear. Methods: The Pass ive I mmunity T rial for O ur N ation (PassITON), is a multicenter, placebo-controlled, blinded, randomized clinical trial being conducted in the United States to provide high-quality evidence on the efficacy of COVID-19 convalescent plasma as a treatment for adults hospitalized with symptomatic disease. Adults hospitalized with COVID-19 with respiratory symptoms for less than 14 days are eligible. Enrolled patients are randomized in a 1:1 ratio to 1 unit (200-399 mL) of COVID-19 convalescent plasma that has demonstrated neutralizing function using a SARS-CoV-2 chimeric virus neutralization assay. Study treatments are administered in a blinded fashion and patients are followed for 28 days. The primary outcome is clinical status 14 days after study treatment as measured on a 7-category ordinal scale assessing mortality, respiratory support, and return to normal activities of daily living. Key secondary outcomes include mortality and oxygen-free days. The trial is projected to enroll 1000 patients and is designed to detect an odds ratio ≤ 0.73 for the primary outcome. Discussion: This trial will provide the most robust data available to date on the efficacy of COVID-19 convalescent plasma for the treatment of adults hospitalized with acute moderate to severe COVID-19. These data will be useful to guide the treatment of COVID-19 patients in the current pandemic and for informing decisions about whether developing a standardized infrastructure for collecting and disseminating convalescent plasma to prepare for future viral pandemics is indicated. Trial Registration: ClinicalTrials.gov: NCT04362176. Date of trial registration: April 24, 2020, https://clinicaltrials.gov/ct2/show/NCT04362176.

6.
Lancet ; 393(10175): 1021-1032, 2019 Mar 09.
Artículo en Inglés | MEDLINE | ID: mdl-30739747

RESUMEN

BACKGROUND: Acute stroke due to supratentorial intracerebral haemorrhage is associated with high morbidity and mortality. Open craniotomy haematoma evacuation has not been found to have any benefit in large randomised trials. We assessed whether minimally invasive catheter evacuation followed by thrombolysis (MISTIE), with the aim of decreasing clot size to 15 mL or less, would improve functional outcome in patients with intracerebral haemorrhage. METHODS: MISTIE III was an open-label, blinded endpoint, phase 3 trial done at 78 hospitals in the USA, Canada, Europe, Australia, and Asia. We enrolled patients aged 18 years or older with spontaneous, non-traumatic, supratentorial intracerebral haemorrhage of 30 mL or more. We used a computer-generated number sequence with a block size of four or six to centrally randomise patients to image-guided MISTIE treatment (1·0 mg alteplase every 8 h for up to nine doses) or standard medical care. Primary outcome was good functional outcome, defined as the proportion of patients who achieved a modified Rankin Scale (mRS) score of 0-3 at 365 days, adjusted for group differences in prespecified baseline covariates (stability intracerebral haemorrhage size, age, Glasgow Coma Scale, stability intraventricular haemorrhage size, and clot location). Analysis of the primary efficacy outcome was done in the modified intention-to-treat (mITT) population, which included all eligible, randomly assigned patients who were exposed to treatment. All randomly assigned patients were included in the safety analysis. This study is registered with ClinicalTrials.gov, number NCT01827046. FINDINGS: Between Dec 30, 2013, and Aug 15, 2017, 506 patients were randomly allocated: 255 (50%) to the MISTIE group and 251 (50%) to standard medical care. 499 patients (n=250 in the MISTIE group; n=249 in the standard medical care group) received treatment and were included in the mITT analysis set. The mITT primary adjusted efficacy analysis estimated that 45% of patients in the MISTIE group and 41% patients in the standard medical care group had achieved an mRS score of 0-3 at 365 days (adjusted risk difference 4% [95% CI -4 to 12]; p=0·33). Sensitivity analyses of 365-day mRS using generalised ordered logistic regression models adjusted for baseline variables showed that the estimated odds ratios comparing MISTIE with standard medical care for mRS scores higher than 5 versus 5 or less, higher than 4 versus 4 or less, higher than 3 versus 3 or less, and higher than 2 versus 2 or less were 0·60 (p=0·03), 0·84 (p=0·42), 0·87 (p=0·49), and 0·82 (p=0·44), respectively. At 7 days, two (1%) of 255 patients in the MISTIE group and ten (4%) of 251 patients in the standard medical care group had died (p=0·02) and at 30 days, 24 (9%) patients in the MISTIE group and 37 (15%) patients in the standard medical care group had died (p=0·07). The number of patients with symptomatic bleeding and brain bacterial infections was similar between the MISTIE and standard medical care groups (six [2%] of 255 patients vs three [1%] of 251 patients; p=0·33 for symptomatic bleeding; two [1%] of 255 patients vs 0 [0%] of 251 patients; p=0·16 for brain bacterial infections). At 30 days, 76 (30%) of 255 patients in the MISTIE group and 84 (33%) of 251 patients in the standard medical care group had one or more serious adverse event, and the difference in number of serious adverse events between the groups was statistically significant (p=0·012). INTERPRETATION: For moderate to large intracerebral haemorrhage, MISTIE did not improve the proportion of patients who achieved a good response 365 days after intracerebral haemorrhage. The procedure was safely adopted by our sample of surgeons. FUNDING: National Institute of Neurological Disorders and Stroke and Genentech.


Asunto(s)
Hemorragia Cerebral/cirugía , Procedimientos Quirúrgicos Mínimamente Invasivos/efectos adversos , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Terapia Trombolítica/efectos adversos , Terapia Trombolítica/métodos , Anciano , Femenino , Humanos , Análisis de Intención de Tratar , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
7.
Neurosurgery ; 81(5): 860-866, 2017 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-28402516

RESUMEN

BACKGROUND: Minimally invasive thrombolytic evacuation of intracerebral hematoma is being investigated in the ongoing phase III clinical trial of Minimally Invasive Surgery plus recombinant Tissue plasminogen activator for Intracerebral hemorrhage Evacuation (MISTIE III). OBJECTIVE: To assess the accuracy of catheter placement and efficacy of hematoma evacuation in relation to surgical approach and surgeon experience. METHODS: We performed a trial midpoint interim assessment of 123 cases that underwent the surgical procedure. Accuracy of catheter placement was prospectively assessed by the trial Surgical Center based on prearticulated criteria. Hematoma evacuation efficacy was evaluated based on absolute volume reduction, percentage hematoma evacuation, and reaching the target end-of-treatment volume of <15 mL. One of 3 surgical trajectories was used: anterior (A), posterior (B), and lobar (C). Surgeons were classified based on experience with the MISTIE procedure as prequalified, qualified with probation, and fully qualified. RESULTS: The average hematoma volume was 49.7 mL (range 20.0-124), and the mean evacuation rate was 71% (range 18.4%-99.8%). First placed catheters were 58% in good position, 28% suboptimal (but suitable to dose), and 14% poor (requiring repositioning). Posterior trajectory (B) was associated with significantly higher rates of poor placement (35%, P = .01). There was no significant difference in catheter placement accuracy among surgeons of varying experience. Hematoma evacuation efficacy was not significantly different among the 3 surgical approaches or different surgeons' experience. CONCLUSION: Ongoing surgical education and quality monitoring in MISTIE III have resulted in consistent rates of hematoma evacuation despite technical challenges with the surgical approaches and among surgeons of varying experience.


Asunto(s)
Hemorragia Cerebral/cirugía , Fibrinolíticos/uso terapéutico , Hematoma/cirugía , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Activador de Tejido Plasminógeno/uso terapéutico , Adulto , Catéteres/efectos adversos , Hemorragia Cerebral/tratamiento farmacológico , Terapia Combinada , Femenino , Hematoma/tratamiento farmacológico , Humanos , Masculino , Estudios Prospectivos , Resultado del Tratamiento
8.
Lancet Neurol ; 15(12): 1228-1237, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27751554

RESUMEN

BACKGROUND: Craniotomy, according to the results from trials, does not improve functional outcome after intracerebral haemorrhage. Whether minimally invasive catheter evacuation followed by thrombolysis for clot removal is safe and can achieve a good functional outcome is not known. We investigated the safety and efficacy of alteplase, a recombinant tissue plasminogen activator, in combination with minimally invasive surgery (MIS) in patients with intracerebral haemorrhage. METHODS: MISTIE was an open-label, phase 2 trial that was done in 26 hospitals in the USA, Canada, the UK, and Germany. We used a computer-generated allocation sequence with a block size of four to centrally randomise patients aged 18-80 years with a non-traumatic (spontaneous) intracerebral haemorrhage of 20 mL or higher to standard medical care or image-guided MIS plus alteplase (0·3 mg or 1·0 mg every 8 h for up to nine doses) to remove clots using surgical aspiration followed by alteplase clot irrigation. Primary outcomes were all safety outcomes: 30 day mortality, 7 day procedure-related mortality, 72 h symptomatic bleeding, and 30 day brain infections. This trial is registered with ClinicalTrials.gov, number NCT00224770. FINDINGS: Between Feb 2, 2006, and April 8, 2013, 96 patients were randomly allocated and completed follow-up: 54 (56%) in the MIS plus alteplase group and 42 (44%) in the standard medical care group. The primary outcomes did not differ between the standard medical care and MIS plus alteplase groups: 30 day mortality (four [9·5%, 95% CI 2·7-22.6] vs eight [14·8%, 6·6-27·1], p=0·542), 7 day mortality (zero [0%, 0-8·4] vs one [1·9%, 0·1-9·9], p=0·562), symptomatic bleeding (one [2·4%, 0·1-12·6] vs five [9·3%, 3·1-20·3], p=0·226), and brain bacterial infections (one [2·4%, 0·1-12·6] vs zero [0%, 0-6·6], p=0·438). Asymptomatic haemorrhages were more common in the MIS plus alteplase group than in the standard medical care group (12 [22·2%; 95% CI 12·0-35·6] vs three [7·1%; 1·5-19·5]; p=0·051). INTERPRETATION: MIS plus alteplase seems to be safe in patients with intracerebral haemorrhage, but increased asymptomatic bleeding is a major cautionary finding. These results, if replicable, could lead to the addition of surgical management as a therapeutic strategy for intracerebral haemorrhage. FUNDING: National Institute of Neurological Disorders and Stroke, Genentech, and Codman.


Asunto(s)
Hemorragia Cerebral/tratamiento farmacológico , Hemorragia Cerebral/cirugía , Fibrinolíticos/farmacología , Evaluación de Resultado en la Atención de Salud , Hemorragia Posoperatoria/etiología , Trombectomía/métodos , Activador de Tejido Plasminógeno/farmacología , Anciano , Hemorragia Cerebral/mortalidad , Terapia Combinada , Femenino , Fibrinolíticos/administración & dosificación , Fibrinolíticos/efectos adversos , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Procedimientos Quirúrgicos Mínimamente Invasivos , Cirugía Asistida por Computador , Trombectomía/efectos adversos , Activador de Tejido Plasminógeno/administración & dosificación , Activador de Tejido Plasminógeno/efectos adversos
9.
Stroke ; 44(3): 627-34, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23391763

RESUMEN

BACKGROUND AND PURPOSE: Perihematomal edema (PHE) can worsen outcomes after intracerebral hemorrhage (ICH). Reports suggest that blood degradation products lead to PHE. We hypothesized that hematoma evacuation will reduce PHE volume and that treatment with recombinant tissue-type plasminogen activator (rt-PA) will not exacerbate it. METHODS: Minimally invasive surgery and rt-PA in ICH evacuation (MISTIE) phase II tested safety and efficacy of hematoma evacuation after ICH. We conducted a semiautomated, computerized volumetric analysis on computed tomography to assess impact of hematoma removal on PHE and effects of rt-PA on PHE. Volumetric analyses were performed on baseline stability and end of treatment scans. RESULTS: Seventy-nine surgical and 39 medical patients from minimally invasive surgery and rt-PA in ICH evacuation phase II (MISTIE II) were analyzed. Mean hematoma volume at end of treatment was 19.6±14.5 cm(3) for the surgical cohort and 40.7±13.9 cm(3) for the medical cohort (P<0.001). Edema volume at end of treatment was lower for the surgical cohort: 27.7±13.3 cm(3) than medical cohort: 41.7±14.6 cm(3) (P<0.001). Graded effect of clot removal on PHE was observed when patients with >65%, 20% to 65%, and <20% ICH removed were analyzed (P<0.001). Positive correlation between PHE reduction and percent of ICH removed was identified (ρ=0.658; P<0.001). In the surgical cohort, 69 patients underwent surgical aspiration and rt-PA, whereas 10 underwent surgical aspiration only. Both cohorts achieved similar clot reduction: surgical aspiration and rt-PA, 18.9±14.5 cm(3); and surgical aspiration only, 24.5±14.0 cm(3) (P=0.26). Edema at end of treatment in surgical aspiration and rt-PA was 28.1±13.8 cm(3) and 24.4±8.6 cm(3) in surgical aspiration only (P=0.41). CONCLUSIONS: Hematoma evacuation is associated with significant reduction in PHE. Furthermore, PHE does not seem to be exacerbated by rt-PA, making such neurotoxic effects unlikely when the drug is delivered to intracranial clot.


Asunto(s)
Edema Encefálico/prevención & control , Hemorragia Cerebral/terapia , Fibrinolíticos/uso terapéutico , Hematoma/complicaciones , Procedimientos Quirúrgicos Mínimamente Invasivos , Activador de Tejido Plasminógeno/uso terapéutico , Anciano , Edema Encefálico/diagnóstico por imagen , Edema Encefálico/epidemiología , Femenino , Hematoma/diagnóstico por imagen , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Proteínas Recombinantes/uso terapéutico , Succión/métodos , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...